AP-AB1205 AC electroshock-proof ion bar is the bar shape static eliminator used to remove electrostatic on object surface.
AP - AB1205 AC electroshock-proof ion bar generates positive and negative ion on emitter by AC high voltage and transfer the ion to the object surface to be static removed. Thus neutralize the ion on the object surface and eliminate static efficiently and reliably. .


Features
(1)Bar shaped and cross over static eliminator
(2)Compact structure and elegant appearance
(3)Fast discharge speed, low ion balance and high safety performance
(4)Abnormal high voltage alarm function
(5)Electroshock-proof function



Performance parameter
Model       AP-AB1205
Output voltage DC 24V
Input Current 600mA
Power     10W
Output voltage DC±5KV  
Ion emission AC
Transmitting electrode SUS
Discharge structure Resistance coupling
Output frequency 1,3,5,10,20,30,50Hz(Factory settings30Hz)
Duty factor 10%—90%
Discharge range       L*W*H{200mm210-410mm(Needle spacing:25mm)460-2960mm(Needle spacing:50mm)}*300*100mm
Installation distance 30→100mm
Ion balance   ≤|±30V|AVE
Discharge time   ≤1Stesting distance:100mm
Alarm High-voltage alarm indicator (green is normal operation, red is high voltage abnormal)
Operating temperature     0℃-50℃
Working humidity 70%
Dimensions L*W*H{200mm210-410mm(Needle spacing:25mm)460-2960mm(Needle spacing:50mm)}*35*63.5mm
Rod material PVCALSUS
Mounting accessories M5 Mounting bolt, M5 slider nut
Warranty period 1Year
Certificate CE
Testing Data
Testing standard ANST/ESD.STM3.1 ANST/RSD.SP3.3  SJ/T 11446-2013
Testing instrument Trek157
Testing voltage ±1000V→100V
Testing environment Relative humidity50±5%
Temperature:23±3℃
 
◆Use and Installation
(1)Choose an optimal position and fix the ion bar and adaptor tightly.
(2)Connect two ends of power cable with adaptor and ion bar.
(3)Connect the ground end on the bar body to the ground bolt on the power
(4)Switch on the power and set proper parameters.  