The integrated power supply comes with a serial port server. The ESD protection device is connected to the integrated power supply through the RJ45 network port to provide working voltage and data transmission for the product. At the same time, the integrated power supply acts as a data interaction platform, and can connect the ESD protection device and the computer through wireless transmission and wired connection. A single integrated power supply can be connected to the computer via WIFI, or it can be wired to the computer via the RJ45 network port. When multiple units are connected, the wireless routers are connected to the local area network, and then connected to the computer through the router WIFI. The cascading LANs can be connected to the computer through the RJ45 network port.
3) 32-way working status indicator.
4) RJ45 power connector.
5) RS485 and wireless communication functions.
No. | Basic Parameter | ||||||
1 | Input voltage | AC175-240V | |||||
2 | Output voltage | DC24V | |||||
3 | Output current | 12.5A | |||||
4 | Output Power | 300W | |||||
5 | Product Size | 380*160*50 | |||||
6 | Work instructions | LED | |||||
7 | Input indication | Digital display 0.28 Inch LED,monochrome | |||||
8 | Product network port | 32 Port :P1-P32 | |||||
9 | Network port definition | 1、2 | 3 | 4 | 5、6、9 | 7 | 8 |
|
|
White-orange, orange | White- blue | blue | White-green, green | White-brown | brown |
|
|
VCC | RS485_B | RS485_A | GND、PE | NPN-C1 | NPN-C2 |
10 | Communication network port | DC \ PLC \ RS485 \ WAN/LAN | |||||
11 | Illuminated switch | 16 Road:SW1-SW16 | |||||
12 | Working environment | temperature:0-50℃;humidity:30-70% | |||||
13 | Net weight | 2500g | |||||
14 | Gross weight | 2950g | |||||
No. | Function Parameter | ||||||
1 | Network port | P1-P16 | Static eliminator or static sensor | ||||
|
|
P17-P32 | static sensor | ||||
2 | Network port | WAN/LAN | Ethernet connection | ||||
|
|
RS485 | RS485 way | ||||
|
|
PLC | |
||||
|
|
DC_24V | Supply external equipment power | ||||
3 | Illuminated switch | SW1-SW16 | Control the heater on and off (with green indicator light) | ||||
4 | LED | P1-P32 | Red | Static eliminator | High voltage indication | flicker | |
|
|
|
|
Static eliminator | Threshold indication | |
|
|
|
|
Green | Static eliminator | Power on indication | Constantly bright | |
|
|
|
|
static sensor | |
|
|
|
|
|
|
Static eliminator | Cleaning instructions | flicker | |
Note:1、P1 - P32 : Due to power supply limitations, up to 20 consumers can be loaded. |