Frequency conversion air insulation portable X-ray generator can be widely used in
shipbuilding, machinery manufacturing,aviation, rail, pressure vessels, boilers,
oil, chemical, defense industry and other departments for non-destructive testing.
Particularly applicable to construction site operation and high-altitude operations.
 

1.Controller
(1)The special design of high frequency technology can avoid the 
interference by power spikes.Even though the voltage changes,it can still work.
(2)All the signal wires in the controller are imported from South Korea to improve
the  quality. 
(3)Take the isolation technology of the low  voltage and the high voltage to ensure

the controller working steady.
(4)Posses the reliable "time-delayed" function, suitable to operate in the open field. 
(5)High degree of automation with the function of trouble shooting and indication.

(6)Controller adopts design of hardware with a wide operative range,having the   
advantage of long service and low failure rate.
(7)Strictly comply with 1:1 working/resting regulation,eliminating the disoperation.
 

2.Generator
(1)Safe and reliable generator adopts design of SF6 gaseous  insulator,
grounded-anode,and air fan cooling.
(2)High purity and high density aluminium radiator is specially designed for our  
instrument.High temperature installation technology is adopted to improve 30%
heat radiation.
(3)The HV coils made by imported enamel wire are applied in the X-ray generator,
so as to make the quality of the complete equipment improved a great deal.
(4)The new technology can guarantee the machine to keep shooting for 30 minutes.
 
3. Connecting Cable
The length is 25m,much longer than the limited length by the international
standard.It can guarantee the safety of the operator.

Classify

Beam

angle

 Model 

No.

Tube

 voltage

 (KV)

Capacity

  (KW)

Focus

 size

(mm)

Max.

penetra-

tion

 A3 steel

  (mm)

X-ray

generator   

Size

(mm)

Weight

 (kg)

Glass

tube

directional

 40°

XXQ-

P1005

40-

100

>1.0

1.0*1.0

8

180*180

*540

10

XXQ-

P1605

60-

160

>1.5

1.5*1.5

20

210*210

*620

15

XXQ-

P2005

80-

200

>2.0

1.5*1.5

29

290*290

*680

23

XXQ-

P2505

130-

250

>2.5

2.0*2.0

39

320*320

*730

35

XXQ-

P3005

150-

300

>3.0

2.5*2.5

49

340*340

*850

43

XXQ-

P3505

200-

350

>3.5

2.5*2.5

59

340*340

*820

42

 

Glass

tube

panoramic

with flat

target

360°

*25°

XXH-

P1005

40-

100

>1.0

1.0*1.5

6

160*160

*520

11

XXH-

P1605

60-

160

>1.5

1.0*2.0

18

210*210

*620

15

XXH-

P2005

80-

200

>2.0

1.0*2.0

26

270*270

*665

20

XXH-

P2505

130-

250

>2.5

1.0*2.4

36

330*330

*750

32

XXH-

P3005

150-

300

>3.0

1.0*2.5

46

330*330

*765

41

XXH-

P3505

200-

350

>3.5

1.0*2.5

56

340*340

*820

42

 

Glass

tube

panoramic

with cone

target

360°

*40°

XXHA-

P1605

60-

160

>1.5

1.0*3.5

15

210*210

*620

15

XXHA-

P2005

80-

200

>2.0

1.0*3.5

24

290*290

*685

23

XXHA-

P2505

130-

250

>2.5

1.0*5.0

34

330*330

*750

35

XXHA-

P3005

150-

300

>3.0

1.0*6.0

40

340*340

*850

41

XXHA-

P3505

200-

350

>3.5

1.0*6.0

50

340*340

*850

42

 

Ceramic tube

directional

 40°

XXG-

P1605

60-

160

>1.5

1.5*1.5

20

230*200

*570

14

XXG-

P2005

80-

200

>2.0

1.5*1.5

29

290*290

*620

26

XXG-

P2505

130-

250

>2.5

2.0*2.0

39

330*330

*710

32

XXG-

P3005

150-

300

>3.0

2.5*2.5

49

340*340

*850

37

XXG-

P3505

200-

350

>3.5

2.5*2.5

59

330*330

*670

38

 

Tube Current

5mA

Power Supply

AC220V ±10%  50HZ

Controller Size (mm)

367×320×164

Controller

Weight  (kg)

13kg

Insulating Material

SF6 gas

Working

 Temperature

-25°~ +40°

Relative Humidity

≤85%

 

Standard  

Condition

Focus : 600mm

 Time of exposure :5min

Film :Kodak brand film, double-sided lead film

Film Developing : temperature ±2℃,

developing 5min ,Density ≥2.0

  Safe Pressure

0.35-0.50 MPa(Prohibition of use when it is lower than 0.35 MPa)

5.Working principle description

1. The controller using Silicon controlled rectifier bridge single-phase electric appliances,

the rectified voltage is smoothed by the LC filter circuit into a DC voltage. The voltage of the

thyristor chopper circuit into a variable frequency pulse in one direction, to give high-voltage

pulse transformer as the X-ray generator power supply.Milliamps (mA) units can change

unidirectional pulse frequency with the increase or decrease of x ray tube heating voltage,

to ensure the stability of X-ray tube current.Kilovolt (kV) control unit can continuously control

the tube voltage level to meet the requirements of different materials radiography.

Anti-jamming loop Enhanced the control system ability to against high-voltage shock from

the X-ray generator.

2. X-ray generator adopts prevents shock type. X-ray tube anode grounded, and has

over-temperature protection device. Once the temperature is excessively high, the contr-

oller can automatically cut off the pressure, to prevent X-ray tube damage due to overheating.

3. The power supply voltage fluctuations can be automatically adjusted by the controller itself,

in order to get a stable X-ray. Exposure time and the state machine are controlled by asingle-chip

micro-computer, pre-exposure time of up to 5 minutes.

6 Accessory

Spare Parts

Quantity

X-ray generator

1

Controller

1

Connecting cables

1*25m

Power cable

1*10m

Ground bat

1*5m

Fuse

5

Accessory kit

1

 

 

 

X-ray generator

Controller

Connecting cable

(10 cores) 25m

Power cable

(2cores) 10m

Instruction manual

Earthing wire 5m

Fuse    5PCS

Accessories bag


 

 Inquiry - Portable X-ray Generator