Coating Thickness Gauge
Coating Thickness Gauge

Share:


Coating Thickness Gauge



Coating Thickness Gauge

Features:

1.Using magnetic and eddy current two thickness method can measure the thickness

of the magnetic metal matrix on the non-magnetic coating, can be measured non-

magnetic metal matrix on the thickness of the non-conductive coating;

2.Split (connection between the sensor and the lead instrument), dual (F-type N-type one);

3.The unique temperature compensation algorithm;

4.With two measurements: continuous measurement mode (CONTINUE) and a single measurement (SINGLE);

5.With statistical functions: average value (Here MEAN), maximum value (the MAX),

minimum value (the MIN), the number of tests (NO.), Standard deviation (S.DEV);

6.With storage function: can store 500 measurement values.

 

 

COATING THICKNESS GAUGE SPAREPARTS

C-P01-001

Coated Metal Plates

Epoxy on Steel
(Ferrous)

50x60mm

 

C-P01-0002

Coated Metal Plates

Epoxy on Aluminum
(Non-Ferrous)

50x60mm

 

 

Plastic shims

50,100,250,500,1000 5pcs as one set

--

C-P02-0001

10um

Accuracy±0.3%

C-P02-0002

20um

Accuracy±0.3%

C-P02-0003

50um

Accuracy±0.3%

C-P02-0004

100um

Accuracy±0.6%

C-P02-0005

250um

Accuracy±0.6%

C-P02-0006

500um

Accuracy±0.6%

C-P02-0007

1000um

Accuracy±0.6%

C-P02-0008

2000um

Accuracy±0.6%

C-P02-0009

3000um

Accuracy±0.6%

C-P02-0010

4000um

Accuracy±0.6%

C-P02-0011

5000um

Accuracy±0.6%

C-P02-0012

6000um

Accuracy±0.6%

C-P02-0013

7000um

Accuracy±0.6%

C-P02-0014

8000um

Accuracy±0.6%

C-P02-0015

10000um

Accuracy±0.6%

C-P03-005

Ceramic calibration block

500um

--

C-P03-006

600um

--

C-P03-007

700um

--

C-P03-008

800um

--

C-P03-009

900um

--

C-P03-0010

1000um

--

C-P03-0015

1500um

--

C-P03-0020

2000um

--

C-P03-0025

2500um

--

C-P03-0030

3000um

--

C-P03-0040

4000um

--

C-P03-0080

8000um

--

 

Coating Thickness Probe

Technical parameters

   F-use magnetic probe, based on measurable magnetic metal (such as steel, iron, steel alloys and hard-magnetic, etc.) on non-magnetic coating thickness (such as zinc, aluminum, chromium, copper, rubber, paint, etc.).
    N-type probe use of eddy current way, measurable magnetic non-ferrous metal matrix (such as copper, aluminum, zinc, tin, etc.) and non-conductive, Austenitic stainless steel cover the thickness (such as: rubber, paints, plastics, anodizing film ).
    F / N-probe (except N400) gage with the times and can be used, other brands gage would need change.

 

F1 probe

 F1-use magnetic probe, based on measurable magnetic metal (such as steel, iron, steel alloys and hard-magnetic, etc.) on non-magnetic coating thickness (such as zinc, aluminum, chromium, copper, rubber, paint, etc.).
Measuring principle: magnetic
Measuring range :0-1250 um
Measurement accuracy: one point calibration: ± (3% H +1), two point calibration: ±
(1% H +1)
Low-limit resolution: 0.1
Minimum radius of curvature (convex): 1.5
The smallest diameter: f7
Matrix critical thickness: 0.5

 

F10 probe:
 

F10-use magnetic probe, based on measurable magnetic metal (such as steel, iron,
steel alloys and hard-magnetic, etc.) on non-magnetic coating thickness (such as zinc, aluminum, chromium, copper, rubber, paint, etc.).
Measuring principle: magnetic
Range: 0 - 10mm
Measurement accuracy: one point calibration: ± (3% H +10) ;two point calibration: ±
(1% H +10)
Low-limit resolution: 1
Minimum radius of curvature (convex): 10
The smallest diameter: f40
Matrix critical thickness: 2

 F1/90 probe


F1/90 of the probe using magnetic method, based on measurable magnetic metal
(such as steel, iron, steel alloys and hard-magnetic, etc.) on non-magnetic coating
thickness (such as zinc, aluminum, chromium, copper, rubber, paint, etc.).
Measuring principle: magnetic
Measuring range :0-1250 um
Measurement accuracy: one point calibration: ± (3% H +1);two point calibration: ±
(1% H +1)
Low-limit resolution: 0.1
Minimum radius of curvature (convex): straight
The smallest diameter: f7
Matrix critical thickness: 0.5
 

F400 probe
 

F400-use magnetic probe, based on measurable magnetic metal (such as steel, iron,
steel alloys and hard-magnetic, etc.) on non-magnetic coating thickness (such as zinc,
aluminum, chromium, copper, rubber, paint, etc.).
Measuring principle: magnetic
Measuring range :0-400 um
Measurement accuracy: one point calibration: ± (3% H +0.7) two point calibration: ±
(1% H +1)
Low-limit resolution: 0.1
Minimum radius of curvature (convex): 1
The smallest diameter: f3
Matrix critical thickness: 0.2

N1 probe

 

N1 type eddy current probe the eddy current way, measurable magnetic non-ferrous
metal matrix (such as copper, aluminum, zinc, tin, etc.) and non-conductive,
Austenitic stainless steel cover the thickness (such as: rubber, paints, plastics,
anodizing film )
Measuring principle: Eddy
Measuring range :0-1250 um

Measurement accuracy (um): one point calibration ± (3% H +1.5) ;two point
calibration: ± (1% H +1.5)
Low-limit resolution: 0.1
Minimum radius of curvature (convex): 3
The smallest diameter: f5
Matrix critical thickness: 0.3

 

N400 probe
 

N400-eddy current probe by the eddy current way, measurable magnetic non-ferrous
metal matrix (such as copper, aluminum, zinc, tin, etc.) and non-conductive,
Austenitic stainless steel cover the thickness (such as: rubber, paints, plastics,
anodizing film )
Measuring principle: Eddy
Measuring range :0-400 um

Measurement accuracy (um): one point calibration: ± (3% H +1)
two t point calibration: ± (1% H +1)
Low-limit resolution: 0.1
Minimum radius of curvature (convex): 1.5
The smallest diameter: f4
Matrix critical thickness: 0.3